Brookfield Cap 1000 Viscometer Manual Free Full EPub

Forums: 

Brookfield Cap 1000 Viscometer Manual Free Full EPub

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:Brookfield Cap 1000 Viscometer Manual Free Full EPub.pdf
Size: 3549 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 30 May 2019, 13:52 PM
Rating: 4.6/5 from 762 votes.

Status: AVAILABLE

Last checked: 10 Minutes ago!

In order to read or download Brookfield Cap 1000 Viscometer Manual Free Full EPub ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

Brookfield Cap 1000 Viscometer Manual Free Full EPubBrookfield Engineering Labs., Inc. Page 5 manual No. m02-312-B0315. If you are missing any parts, please notify Brookfield or your local dealer immediately. Any shipping damage must be reported to the carrier. Save the packing container, if possible, for future use when returning the viscometer to Brookfield or an authorized dealer for service. All Brookfield offices and our network of representatives and dealers can be found on our website: www.brookfieldengineering.com Users outside of the European Union: Please dispose of this product according to your local laws. Brookfield Engineering Labs., Inc. Page 9 manual No. m02-312-B0315. PRINt This key sends data to the parallel printer. This key starts spindle rotation. RUN tImE This key selects time entry mode (time of spindle rotation). Figure I-3 Brookfield Engineering Labs., Inc. Page 10 manual No. m02-312-B3215. Brookfield recommends a minimum torque reading of 10 when making viscosity measurements. If the torque value is between 0 and 10, the display will flash to indicate an under range condition. The display will sequentially show BROOKFIELD, then the model of the viscometer and the version number. After about four seconds, the main screen will be displayed (Figure II-1). Cones supplied at the time of order are calibrated to the viscometer by Brookfield prior to shipment, but should still be verified with a calibration check prior to use for the first time. Cones purchased separately at a later time by the user must also be calibrated prior to making viscosity measurements. Then start the test by pressing the RUN key. Press the PRINt key whenever data is desired during the test. Brookfield Engineering Labs., Inc. Page 15. Note: The viscometer will be operating according to the selected parameters while the parameter display screen is shown.Brookfield recommends that viscosity measurements be made between 10 and 100 torque. Brookfield Engineering Labs., Inc. Page 18 manual No. m02-312-B3215.http://egymatec.com/userfiles/a-child-s-history-of-the-world-lesson-manual.xml

    Tags:
  • brookfield cap 1000 viscometer manual, brookfield cap 1000 viscometer manual, brookfield cap 1000 viscometer manual pdf, brookfield cap 1000 viscometer manual instructions, brookfield cap 1000 viscometer manual download, brookfield cap 1000 viscometer manual 2017.

If the test fails again, perform a cone calibration according to the procedure in Section III.4. Brookfield Engineering Labs., Inc. Page 21 manual No. m02-312-B0315. Brookfield Engineering Labs., Inc. Page 23 manual No. m02-312-B0315. Additional weights should only be considered when definitely required and removed when not required.However, with care, the cone can be cleaned in place. Caution: HOT surface. Clean the viscometer plate (refer to Section I.8). Caution: HOT surface. Brookfield Engineering Labs., Inc. Page 26 manual No. m02-312-B3215. The Brookfield publication “More Solutions to Sticky Problems” includes a more detailed discussion of rheological properties and non-Newtonian behavior. Videos posted to our website can be found here as well as other “home-made” videos made by our own technical sales group. Viscosityjournal.com Brookfield is involved with a satellite website that should be your first stop in viscosity research. For a copy of the Repair Return Form, go to the Brookfield website, www.brookfieldengineering.com. PDF Manual Pre Used, however Fully Refurbished by Brookfield in February 2015 The CAP Viscometer was originally designed to provide a high shear rate test for paints and coatings that simulates material behavior in rolling, brushing, and spraying applications. Applications include paints, resins, foods, cosmetics, pharmaceuticals, dispersions, coatings, and inks. Will need to order the appropriateMost methods are single pointHowever, NO WARRANTY IS EXPRESSED OR IMPLIED REGARDING THE ACCURACY OF THESE DATA, THE RESULTS TO BE OBTAINED FROM THE USE THEREOF, OR THAT ANY SUCH USE WILL NOT INFRINGE ANY PATENT. This information is furnished upon the condition that the person receiving it shall make his own tests to determine the suitability thereof for his particular purpose. Shambhavi Impex Navi Mumbai, Dist. Thane Swastik Scientific Instruments Private Limited Thane West, Mumbai. Brochure Centurion Scientific Okhla, New Delhi.http://galatarenova.com/E/a-catullus-workbook-teacher-s-manual.xml Dolphin Pharmacy Instruments Private Limited Kalbadevi, Mumbai Brochure Agaram Industries Mumbai Get Best Deal I agree to the terms and privacy policy Standard operating procedures for the brookfield rvdv-e visc. Measuring the viscosity of semi-solids using brookfield rv v. Viscosity of non-newtonian fluid using brookfield rotational. How to take a viscosity reading with brookfield viscometers Measuring Viscosity of Non-Newtonian Fluids Using a Brookfield DV-II Pro Viscometer Have a Question. Ask our expert Speak your question Please enter your question. Our offered product is read more. Brochure Delta Scientific Equipment Private Limited Shobhabazar, Kolkata The new generation of sophisticated Brookfield Viscometers and Rheometers are world standards for fast, accurate, reliable read more. Brochure Aarkey Labtronix India Delhi Sintrex Corporation Marine Lines, Mumbai Shreeji Instruments Ghodasar, Ahmedabad Get Best Deal I agree to the terms and privacy policy Mayapuri, New Delhi. Jain Laboratory Instruments Private Limited Jain Laboratory Instruments Private Limited, Ambala Esico International Sector 34, Parwanoo, Dist. Solan Sunshine Scientific Equipments Delhi. Atico Medical Ambala Get Best Deal I agree to the terms and privacy policy Ajanta Export Industry Ambala Cantt, Ambala Easy to operate and read more. Brochure Popular Science Apparatus Workshops Pvt. Ltd. Opposite Kali Bari Mandir Gate, Ambala Sharad Agencies Parvati Paytha, Pune Hally Instruments Mumbai We will review and answer your question shortly. Have a question? Ask our expert Get Best Deal I agree to the terms and privacy policy All rights reserved. By continuing to use this website, you consent to our use of these cookies. By continuing to use this website, you consent to our use of these cookies. Using a viscometer and colorimeter guarantees consistent product release and control.https://formations.fondationmironroyer.com/en/node/14269 Although viscosity and colour are basic aspects, a quick successful implementation of a viscometer may need good advice. With a stable. We can offer almost any type of. Keep Reading Keep Reading The DVE display shows torque, spindle and speed, and is the perfect choice for the first time user!. Keep Reading Some manual calculation is required to obtaincentipoises values. Works with a variety of Brookf. Keep Reading Keep Reading Keep Reading Keep Reading Gel coats, resins, and potting compounds are primary example. Keep Reading When gel time is reached, display shows both gel time and equivalent viscosity va. Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading It allows quick, efficient testing for busylabs that need to improve productivity while maintaining quality.. Keep Reading Keep Reading Keep Reading It is ideal for manufacturers who process powders daily and want to minimize or eliminate downtim. Keep Reading Keep Reading Powder Flow Pro operates and controlsthe Powder Flow Tester and is included with purchase of theinstrument.. Keep Reading Keep Reading RheocalcT RheocalcT software can analyze data, generate multiple plotoverlays, print tabular data, run math models and perform other time-savingroutines. Keep Reading Keep Reading Keep Reading Also accommodates 600 mL beaker. Keep Reading Also accommodates a 600 mL beaker. Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Keep Reading Theme: Accelerate by ThemeGrill. FUNGILAB, S.A. was born in 1983, initialy as a company devoted to import and market consumables and laboratory material to the Spanish territory. In 1992 the company technical knowledge and the market trends led us to become manufacturers.http://cleanteclogistics.com/images/caneta-espia-manual.pdf Starting with the TLC tanks, and following with rotational viscosimeters and accessories. As it is our company policy, FUNGILAB, S.A. is always researching to improve our production range as well as to offer our customers new Viscometers versions. FUNGILAB, S.A. is selling Viscometers worldwide through a wide net of specialized dealers to ensure the appropriate technical and sales support. Fungilab Viscometers, TLC's and baths are certified for all of the international standard prodedurals BS, ISO and ASTM like: BS 6075, BS 5350, ISO 2555, ISO 1652, ASTM 115, ASTM 789, ASTM 1076, ASTM 1084, ASTM 1286, ASTM 1417, ASTM 1439, ASTM 1824, ASTM 2196, ASTM 2336, ASTM 2364, ASTM 2393, ASTM 2669, ASTM 2849, ASTM 2983, ASTM 2994, ASTM 3232, ASTM 3236 and ASTM 3716. Essential in investigation and quality control Laboratories.AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards. These are the standards our units follow: BS: 6075, 5350For a minus viscosity of 100 cP: 0.01 cP. For a major viscosity of 1000 cP: 0.1 cP. For a major viscosity of 5000 cP: 1.0 cP. For a major viscosity of 10.000 cP: 5.0 cP. For a major viscosity of 25.000 cP: 10.0 cP. For a major viscosity of 50.000 cP: 25.0 cP. For a major viscosity of 100.000 cP: 100.0 cP. For a major viscosity of 1.000.000 cP: 1.000.0 cPTemperature limits:Type of probe: PT100Sample volume (6.7 - 13 ml.)Sample volume (6.7 - 13 ml.)Sample volume (16 ml.)Sample volume (16 ml.)Accessory for measuring non-flowing substances viscosity (with spindles)Reproduction, modification, distribution or manipulation of any of the aforementioned content is therefore prohibited. Fungilab is the exclusive owner of all intellectual and industrial property rights and any analogous rights that may apply with respect to this Web Site.https://www.edutechusa.com/wp-content/plugins/formcraft/file-upload/server/content/files/163471740ee06f---dacor-oven-troubleshooting-manuals.pdf In addition, all rights over any Content, Services or other elements of its property that are incorporated in this Web Site are reserved in favour of Fungilab. Fungilab reserves the right to update, modify or delete information contained in its web site, or to alter its configuration, functions or general conditions at any time and without previous notice. Fungilab is a company centered in Viscosity and its mesurement. We master all kind of viscosity and devices, such as Kinematic viscosity and others. Every Viscometer made by Fungilab has ben tested to ensure it follows the most strict rules in science. A Fungilab Viscometer is durable and thrustwhorthy. Our team takes all care in making every Viscometer. Everything is taken into consideration. Dynamic viscosity, Centipoises, Centistrokes, Capillary viscosity, Shear rate, Shear stress, Newtonian Fluids and non Newtonian fluids and everything related to viscosity and Rheology. We tend to have a range of Viscometers to mesure every aspect of Viscosity. In particular, Fungilab specializes in Viscometers. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. User-Friendly Manuals. Product Instructions. What Does That Mean? Viscosity measurements are made in conjunction with product quality and efficiency. Anyone involved with flow characterisation, in research or development, quality control or fluid transfer, at one time or another gets involved with some type of viscosity measurement. The selection of the right viscometer from the scores of instruments available to meet the need of any application is a difficult proposition. Today's instruments vary from the simple to the complex: from counting the seconds for a liquid to drain off a stick to very sophisticated automatic recording and controlling equipment.akilciilacdernegi.com/ckfinder/userfiles/files/Dicon-Co850Mi-Manual.pdfThis friction becomes apparent when a layer of fluid is made to move in relation to another layer. The greater the friction, the greater the amount of force required to cause this movement, which is called shear. Shearing occurs whenever the fluid is physically moved or distributed, as in pouring, spreading, spraying, mixing, etc. Highly viscous fluids, therefore, require more force to move than less viscous materials. Two parallel planes of fluid of equal area A are separated by a distance dx and are moving in the same direction at different velocities V1 and V2. Newton assumed that the force required to maintain this difference in speed was proportional to the difference in speed through the liquid, or the velocity gradient. To express this, Newton wrote: This will be symbolized as S in subsequent discussions. Its unit of measure is called the reciprocal second (sec-1). It is referred to as shear stress and will be symbolized by F'.A material requiring a shear stress of one dyne per square centimeter to produce a shear rate of one reciprocal second has a viscosity of one poise, or 100 centipoise. You will encounter viscosity measurements expressed in Pascal-seconds (Pa-s) or milli-Pascal-seconds (mPa-s); these are units of the International System and are sometimes used in preference to the Metric designations. One Pascal-second is equal to ten poise; one milli-Pascal-second is equal to one centipoise. In other words, twice the force would move the fluid twice as fast. Viscosity is more easily measured than some of the properties that affect it, making it a valuable tool for material characterisation. Having identified a particular rheological behavior in a material, you may wonder what this information implies about its other characteristics. Some materials are quite sensitive to temperature, and a relatively small variation will result in a significant change in viscosity. Others are relatively insensitive.https://humantouchtranslations.com/wp-content/plugins/formcraft/file-upload/server/content/files/1\/16347175e31ea9---dacor-oven-parts-manual.pdf Consideration of the effect of temperature on viscosity is essential in the evaluation of materials that will be subjected to temperature variations in use or processing, such as motor oils, greases, and hot-melt adhesives. It would, for example, be disastrous to try to pump a dilatant fluid through a system, only to have it go solid inside the pump, bringing the whole process to an abrupt halt. While this is an extreme example, the importance of shear rate effects should not be underestimated. If these are not known, an estimate should be made. Viscosity measurements should then be made at shear rates as close as possible to the estimated values. In this case, it is necessary to make measurements at several shear rates and extrapolate the data to the projected values. This is not the most accurate method for acquiring this information, but it is often the only alternative available, especially when the projected shear rates are very high. In fact, it is always advisable to make viscosity measurements at several shear rates to detect rheological behavior that may have an effect on processing or use. Where shear rate values are unknown or not important, a sample plot of viscosity versus RPM will often suffice. However, there are several means to narrowing the possibilities before any testing is performed. If a sample has historically been tested using a particular speed and spindle combination, the user should use that same combination. This will help to ensure test results are accurate and repeatable. The objective is to choose a spindle that will produce a dial or digital display reading between 10 and 100 torque. The minimum viscosity that can be measured is equal to 10 times the factor, or one tenth of the full scale range.Enter a spindle code and an RPM setting and press the AUTO RANGE key. The viscometer will calculate and display the full scale range viscosity for that spindle and speed combination.http://frederickfollows.co.uk/wp-content/plugins/formcraft/file-upload/server/content/files/163471779af3f4---dacor-pacer-aero-manual.pdf If the reading is below 10 or above 100, the user should choose a different speed to obtain a reading in the recommended range. If changing speeds doesn't provide readings between 10 and 100, the user should try another spindle. Generally, if the reading is above 100 at the lowest speed, the next smallest spindle should be used. If the reading is below 10 at the highest speed, the next largest spindle should be used. You can check the accuracy of your Viscometer by performing a calibration check. Lab Unlimited Carl Stuart Group perform this Calibration with a Factory Calibrated Master Viscometer to tune your instrument to Factory Specification. Assuming that all other conditions are identical - spindle, speed, temperature, container size, spring torque, etc., a reading produced on a dial reading viscometer is as valid, accurate, and reproducible as a reading produced on a digital viscometer. As temperature increases, viscosity decreases. For this reason, it is critical to control the temperature of a sample during any viscosity measurement. These elements include, but are not limited to, the spindle, guard leg, sample container, sample, and temperature probe. Because temperature is critical to accurate readings, you should allow sufficient time to achieve equilibrium. In general, one hour is the minimum time to wait. The more viscous the material being measured, the longer you should wait. FSR is defined as the highest achievable viscosity reading with a given spindle and speed. The easiest way to determine FSR is by pressing the AUTO RANGE button on your digital viscometer. Pressing this displays FSR for the spindle and speed entered. Taking 1 of this value gives you instrument accuracy. For dial viscometer users, multiplying your factor by 100 gives you FSR. Consequently, you can see that your factor is equal to your instrument accuracy. The first factor is the accuracy of the instrument and the second is the accuracy of the calibration fluid.airbornelabs.com/images/editor/files/Diagnostics-Statistical-Manual-Iv.pdf The total accuracy is the instrument accuracy plus the fluid accuracy. The operator must determine whether the instrument is a high or low temperature CAP, and whether it is a 1000 or 2000 model. Cross referencing that information with the cone-spindle number in use, they will determine a number on the chart. This number is the percent of the full scale range that must be considered as the instrument accuracy. Under these conditions, FSR is 8.333 Poise. From Table 3.1, the percent of FSR calculated for accuracy is 2 or 4, depending on whether the calibration fluid is greater or less than 50 of FSR. The jewel bearing, pivot point and shaft may be worn or bent; perform the calibration check to determine if the viscometer is still performing within calibration. The viscometer is in need of service and recalibration. The modified Casson model, for example, works well for testing chocolates, among other things. It may be tough to accurately predict product behavior. Conservatively used, rheology models may be good for interpolating apparent viscosities at various shear rates, for example. Nonetheless, some models may be used to extrapolate yield stresses, for example, at shear rate values of zero. The more data points taken, the more reliable the fit. That does not mean that it would be the best model to use. The Bingham model assumes Newtonian behavior after yield.That is, for the spindle and speed you have selected, the material is reading higher than the Full Scale Range. Lower the speed or change the spindle to raise the Full Scale Range. Rheocalc-T should be used for acquiring data to a PC when used with DV2T or DV3T. If you have a need that is not covered in this range, please contact our Sales Team. Our Education section may be just the thing to clarify unfamiliar terms and help start you on your way to a better understanding of viscosity. Learn about viscosity and rheological relationships, Newtonian and non-Newtonian fluids, and how a Brookfield instrument can help your production process and much more. HELP ME CHOOSE Having difficulties determining what instrument is best for you. Try our Help Me Choose section for guidance on the model selection process, spindle construction considerations, and other useful information to help you make an informed decision on the best instrument for your application. Having this annual maintenance done will ensure the instrument's long life and optimal performance. For non-Newtonian liquids a digital viscometer that applies a precise shear rate is needed. For laboratory viscosity measurement BYK-Gardner offers a comprehensive line of rotational viscometers. The viscometer product line can measure viscosity from a near water-like viscosity to a very high viscosity range for epoxy, sealants, and paste. To measure viscosity under a high shear rate Cone and Plate viscometers are available. The easy to use digital Stormer viscometer is also part of the rotational viscometer family. Spindle protector, Spindle rack, Quick disconnect accessory, PT100 temperature probe, Datalogger software, USB port, Power cable, Calibration certificate, Spindle protector, Spindle rack, Datalogger software, USB port, Power cable, Calibration certificate, Spindle protector, Spindle rack, Quick disconnect accessory, PT100 Spindle protector, Spindle rack, Quick disconnect accessory, PT100 Manual instrucciones Manual instrucciones Manual de instrucciones Soporte Helipath. Acoplamiento especial. Choice of shear rate. Standard speeds include 750 and 900 rpm to provide shear rate at 10,000 sec. Rapid temperature. Read more. You can search for similar products in our product directory. Standard speeds include 750 and 900 rpm to provide shear rate at 10,000 sec. Easy It’s quick and simple to do Fast Your inquiry will be delivered straight to the manufacturer Free You’re under no obligation Secure We only pass your details on to trusted suppliers at your request Save time Submit your details once and make multiple inquiries. INTRODUCTION. Page 4 and 5: I.1 ComponentsComponent Part Number Page 6 and 7: I.3 SpecificationsSpeeds: 0.0, 0.3, Page 8 and 9: I.6 Key FunctionsFigure I-1 shows t Page 10 and 11: II.Thank you, for helping us keep this platform clean. The editors will have a look at it as soon as possible. Easy to use interface allows operators to change test parameters easily and test like a pro no time. The digital display ensures easy and accurate readout of test results for simultaneous measurement of viscosity and torque. Quality of manufacture guarantees reliable performance and long life. Measures viscosity and temperature simultaneously (with an optional temperature probe) with a choice of 18 different speeds. With its timed measurement function, data can easily be sent to a PC or printer. The DV2T also offers powerful new programming capabilities and results analysis including data averaging and QC limits with alarms. Test Data can be recorded directly on a local printer or sent to a PC. Additional automated control and data collection can be achieved with optional RheocalcT software. It is an easy-to-use, stand-alone instrument for measuring viscosity and yield stress. It’s available in a Standard version and a 21 CFR Part 11 Compliant version. Standard speeds include 750 and 900 rpm to provide shear rate at 10,000 sec-1. The Small Sample Adapter’s rheologically correct cylindrical geometry provides extremely accurate viscosity measurements and shear rate determinations. The design of the SSA allows the sample chamber to be easily changed and cleaned without disturbing the set-up of the viscometer or temperature bath. This means that successive measurements can be made under identical conditions. The sample chamber fits into a flow jacket so that precise temperature control can be achieved when a Brookfield circulating temperature bath is used.Newtonian and non-Newtonian materials can be measured. It is most commonly used with the LV series instrument (at 60 rpm, these models have a full scale range of 1-10 cP with the UL Adapter). Temperature ramping between set points is possible if used with RheocalcT Software The drive motor slowly lowers or raises the viscometer so that the T-bar spindle creates a helical path through the test sample thus eliminating the problem of “channeling”. A wide range of shear rate, shear stress, and torque provide flexible flow analysis including creep and yield measurement. The RST-CC Rheometer is designed to accommodate the high throughput required of quality control laboratories providing cost effective, worry free operation for a variety of laboratory applications. Rheological evaluation through controlled stress and controlled rate measurements provide comprehensive viscosity flow curves, thixotropic response, yield stress determination creep analysis and viscosity vs.Whether you are testing the consistency of pills and tablets, the peel ability of a yogurt lid, or the tensile strength of lipstick, our new CTX will meet your ever-growing testing needs. It also is great in QC applications where data can be sent or saved in multiple formats. With six built-in test modes and ten memory slots for operator-protected tests with administrator rights, a wide choice of accessories and an optional software package, the CT3 is perfect for most any physical testing requirements. The CT3 performs like a high-end texture analyser but at a fraction of the cost.It is ideal for manufacturers who process powders daily and want to minimize or eliminate downtime and expense that can occur when hoppers discharge erratically or fail to discharge altogether. Brookfield Viscosity Standards are certified by methods traceable to the United States National Institute of Standards and Technology (NIST). The selection of one or two fluids will normally provide sufficient measurement points to verify calibration of your instrument. All fluids are supplied in. Rotational speed selection ranges from 5 to 1000 RPM. Viscosity measurement ranges depend upon the cone spindle and the rotational speed (shear rate). Page 6 Please check to be sure that you have received all components and that there is no damage. If you are missing any parts, please notify Brookfield or your local dealer immediately. Store the foam insert for future use when shipping or transporting CAP Viscometer. Page 10 I.6 Safety Symbols and Precautions Safety Symbols The following explains safety symbols which may be found in this operating manual. Indicates hazardous voltages may be present. Refer to the manual for specific warning or caution information to avoid personal injury or damage to the instrument. Safety Overview If this instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. Page 11 HOLD TIME This key selects time entry mode (wait time before spindle rotates). SPINDLE This key selects the cone spindle entry mode. If the viscosity measurement is over range, “EEEE” will be displayed. Page 12 II. GETTING STARTED II.1 Power On Turn the power ON using the switch located on the rear of the base console. The start-up screen will be displayed for four seconds and will indicate the viscometer model, version number and torque range. The CAP cones have viscosity ranges as shown in Tables III-1 and III-2. After selecting the appropriate cone for the viscosity range to be utilized, carefully attach the cone to the viscometer as shown in Figure II-3. Be sure to insert the spindle completely into the adapter sleeve; align the flat (see Figure I-1) on the spindle with the thumb screw and then tighten. Page 14 Spindle 04 CALIBRATE. Cones supplied at the time of order are calibrated to the viscometer by Brookfield prior to shipment, but should still be verified with a calibration check prior to use for the first time. Cones purchased separately at a later time by the user must also be calibrated prior to making viscosity measurements. Page 15 II.4 Temperature Control Setting Press the TEMP key and the current temperature setting will blink. Longer runs times are recommended at lower speeds. This provides a comprehensive capability to analyze materials for viscosity behavior as a function of both shear rate and temperature. Tests can be run in standalone mode or under PC control. When calibration is complete, spindle rotation will stop and the “CALIBRATION COMPLETE” screen is displayed. (See Figure III-2). Press ENTER to continue. CALIBRATION COMPLETE PRESS ENTER TO CONTINUE If the viscometer is connected to a printer, the display will show “Press Print or Press Enter to continue”. Press the PRINT key and the printout (Figure III-3) will automatically be generated. Page 26 III.6 Making Viscosity Measurements The following procedure is recommended for making a viscosity measurement. With the viscometer on a clean, level surface, connect it to the proper power supply (Section I.4). 1. Turn the power switch ON (Section II.1). The procedure assumes that the following have been done: a) If the viscometer has been “off” for an extended period (i.e., overnight) a “warm up” period of 30 minutes is suggested. You may choose to warm up at the temperature of test. Page 27 Notes: a. b. c. Lower the handle gently.CAPCALC for Windows requires Windows Windows NT or higher. CAPCALC application software displays, prints and stores tabulated data files (Brookfield, Excel). CAPCALC software has automatic data capture (up to 200 data points per test) and graphical data display (rheograms) to facilitate analysis of test samples.