Breezeaccess Xl Manual |[EBooks]

Forums: 

Breezeaccess Xl Manual |[EBooks]

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:Breezeaccess Xl Manual |[EBooks].pdf
Size: 1707 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 19 May 2019, 14:41 PM
Rating: 4.6/5 from 648 votes.

Status: AVAILABLE

Last checked: 13 Minutes ago!

In order to read or download Breezeaccess Xl Manual |[EBooks] ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

Breezeaccess Xl Manual |[EBooks]Alvarion Ltd. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual or equipment supplied with it. BreezeACCESS VL System Manual Legal Rights. In any event, Alvarion is not liable for any injury, damage or regulation violations associated with or caused by installation, grounding or lightning protection. Some of the equipment provided by Alvarion and specified in this manual, is manufactured and warranted by third parties. All such equipment must be. In addition, a description of all traps relevant to the BreezeACCESS VL devices is provided.BreezeACCESS VL is designed to enable construction of “mixed” cells, where it can be used together with other BreezeACCESS products using GFSK modulation, including BreezeACCESS II, BreezeACCESS MMDS, BreezeACCESS XL and BreezeACCESS V. Base Station Equipment (BS): BreezeACCESS VL Access Units and supporting equipment. Management Systems: SNMP-based Management, Billing and Customer Care, and other Operation Support Systems. NOTE For convenience, all references to AU-BS are applicable also for AUS-BS, unless explicitly stated otherwise. BreezeACCESS VL System Manual. The Subscriber Unit provides an efficient platform for high speed Internet and Intranet services. The use of packet switching technology provides the user with a connection to the network that is always on, enabling immediate access to services. The point-to-point link from the Base Station to the backbone can be either wired or wireless. BreezeACCESS VL components can be managed using standard management tools through SNMP agents that implement standard and proprietary MIBs for remote setting of operational modes and parameters. Embedded with the entire knowledge base of BWA network operations, AlvariSTAR is a unique state-of-the-art power multiplier in the hands of the service provider that enables the provisioning of satisfied customers.http://danipa.com/danipa/admin/images/sidebar/04-zx636-service-manual.xml

    Tags:
  • breezeaccess xl manual, breezeaccess xl manual pdf, breezeaccess xl manual download, breezeaccess xl manual free, breezeaccess xl manual online.

NOTE Installation requirements for SU-I are provided in section 2.5 on page 48. Use only Category 5E Ethernet cables from approved manufacturers, listed in Table 2-2. Consult with Alvarion specialists on the suitability of other cables. Table 2-2: Approved Category 5E Ethernet Cables Manufacturer Superior Cables Ltd. Alvarion and its resellers or distributors are not liable for injury, damage or regulation violations associated with the installation of Outdoor Units or antennas. The location of the indoor equipment should take into account its connection to a power outlet and the customer’s equipment. Installation. In any event, Alvarion is not liable for any injury, damage or regulation violations associated with or caused by installation, grounding or lightning protection. BreezeACCESS VL System Manual. If for any reason the ODU is not used with the IDU with which it was shipped, the MAC Address of the system is in accordance with the marking on the ODU. To expose the groove, lightly squeeze the cap. Carefully insert the cable with the assembled connector through the groove.Put the sealing cap back in its place. Make sure that the small protrusion on the side of the cap fits inside the hole on the connector's protective body. Figure 2-11: Connecting the IDU COM connector and inserting the Sealing Cap Use appropriate sealing material to protect the connection against moisture and humidity. BreezeACCESS VL System Manual. TFTP server SW is required for downloading SW versions. Other installation tools and materials (means for securing cables to walls, etc.). Blinking Amber: Testing (not ready for operation) Red: Self-test failed. It can also be wall mounted using the optional bracket available from Alvarion. It uses a detached antenna. Instructions for the available installation options of the detached antenna. Connect the RF cable supplied with the antenna to the SMA jack located on the unit’s front panel. For installation instructions see Section 2.5.5.2.http://www.lipakeda.nl/uploaded/04-06-r1-service-manual.xml Figure 2-14: SU-I Wall Mount BreezeACCESS VL System Manual. For installation instructions see Section Window mounting kit with rotation capability, enabling installation on a glass window (with rotation capability for adjusting the direction). For installation instructions see Section NOTE Ensure that the antenna is mounted vertical to the floor, with the connector facing downward, and. Note, the Wall-H plate is the one with the horizontal ellipse on the short side. Make sure the inscriptions are facing upwards. Use two M5 screws to fasten the plates together. Do not over tighten. BreezeACCESS VL System Manual. Use the two remaining M5 screws to fasten them. Fasten the antenna to the wall. Connect the antenna cable to the connector located on the bottom side of the antenna. Use only the torque key supplied with the antenna. Do not use a wrench or a similar tightening tool. Figure 2-17: Window Mounting the Antenna BreezeACCESS VL System Manual. Attach the rotation bars to the antenna and the suction cups to the rotation bars. Indicates that the 54V power supply module is OK Green LED. Indicates that the 3.3V power supply module is OK Red LED. Indicates an over temperature condition in the power supply module BreezeACCESS VL System Manual. Figure 2-21 shows the BS-PS-DC front panel. Figure 2-21: BS-PS-DC Front Panel The BS-PS-DC provides a power input connector, marked -48VDC, for connecting the -48 VDC power source to the module. The RADIO port supplies DC power to the ODU, and this may harm other equipment connected to it. The recessed RESET switch on the front panel is for resetting the outdoor unit. Figure 2-22: BS-AU Front Panel BreezeACCESS VL System Manual. To install the BS SH chassis and modules: Install the BS-SH chassis in a 19” cabinet.Reset the unit using the RESET button after connecting or reconnecting the indoor and outdoor units with the indoor-to-outdoor cable. BreezeACCESS VL System Manual.http://eco-region31.ru/94-hyundai-excel-repair-manual This enables the installer to perform the entire process of configuring basic parameters, aligning the antenna and verifying proper operation of the unit right after completing the installation, minimizing the number of times the installer must climb to the roof. It is recommended that a 2 dB margin be added to compensate for possible measurement inaccuracy or variance in the quality of the link. BreezeACCESS VL System Manual. BreezeACCESS VL System Manual Functionality. Table 3-6 provides information for the BS-AU IDU LEDs. Table 3-7 lists the LEDs of the PS1073 IDU. BreezeACCESS VL System Manual Functionality. Blinking Amber: Testing (not ready for operation) Red: Self-test failed.Type “Recover” at the prompt to get a challenge string consisting of 8 characters. Contact Alvarion's Customer Service and give them the challenge string (after user identification) to receive a one-time password. BreezeACCESS VL System Manual. Available at all access levels. If the DFS Option is enabled and the SU is currently looking for its previous AU, the AU’s MAC Address will be displayed. ASSOCIATED: The SU is associated with an AU. BreezeACCESS VL System Manual. If the unit is not associated with any AU, the address defaults to the IEEE broadcast address, which is FF-FF-FF-FF-FF-FF. Unit Hardware Version: The version of the outdoor unit hardware. Unit BOOT Version: The version of the BOOT SW. BreezeACCESS VL System Manual. After reset, any modifications made to the system parameters are applied. 4.2.3.2 Default Settings The Set defaults submenu enables resetting the system parameters to a predefined set of defaults or saving the current configuration as the set of Operator Defaults. Select from the following options: for a list of the default passwords for each of the access levels. BreezeACCESS VL System Manual. The unit is reset automatically. Following the next reset the unit will switch to the main version.https://christiansymbolkits.com/images/cal-grant-manual.pdf Use Running Version After Reset: Defines the current running version as the new main version. BreezeACCESS VL System Manual. Valid values: A string of up to 35 printable ASCII characters. The default system location is an empty string. BreezeACCESS VL System Manual. The event log is an important debugging tool and a flash memory sector is dedicated for storing it. Events are classified according to their severity level: Message (lowest severity), Warning, Error or Fatal (highest severity). Valid values: A string of up to 18 printable ASCII characters. The default is: vx BreezeACCESS VL System Manual. NOTE There is one set of general FTP parameters (FTP Server IP Address, FTP Gateway IP Address, FTP User Name and FTP Password).BreezeACCESS VL System Manual. BreezeACCESS VL System Manual. Typically, transmission events include cases where transmission of a frame was delayed or was aborted before completion. The following additional counters are displayed to indicate the reason for and the nature of the event: 4.2.6.5.10 BreezeACCESS VL System Manual. Underrun: The number of times that transmission of a frame was aborted because the rate of submitting frames for transmission exceeds the available transmission capability. BreezeACCESS VL System Manual. The Link quality submenu includes the following options: 4.2.5.3.1 Continuous Average SNR Display The Continuous Average SNR Display option displays continuously updated information regarding the average quality of the received signal, using Signal to Noise Ratio (SNR) measurements. The MAC address of the internal Operating System stack, which also appears twice. Alvarion's Multicast address (01-20-D6-00-00-01, which also appears twice. The system treats this address as a Broadcast address. The Ethernet Broadcast address (FF-FF-FF-FF-FF-FF).https://spazmedia.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629da445ab2e7---creative-zen-v-manual-online.pdf An SU is only removed from the list of associated SUs under the following conditions: A SNAP frame is received from another AU indicating that the SU is now associated with the other AU. This is the number of currently associated SUs.An SU is only removed from the list of associated SUs under the following conditions: A SNAP frame is received from another AU indicating that the SU is now associated with the other AU. The MAC address if the internal Operating System’s stack, which also appears twice. Alvarion's Multicast address (01-20-D6-00-00-01), which also appears twice. Alvarion's special Multicast address (01-20-D6-00-00-05), reserved for future use. The statistics show the number of frames accumulated in different categories since the last reset. For SUs, the Per Modulation Level Counters display the following information for each modulation level supported by the unit: SUCCESS: The total number of successfully transmitted unicasts at the applicable modulation level. For each relevant unit, identified by its MAC address, the following details are displayed: Security Mode: WEP, AES OCB or FIPS 197. BreezeACCESS VL System Manual. Data Encryption Option: Enable or Disable. 4.2.5.6.4 Show Link Capability by AU (SU only) Select this option to view all capabilities information (General, wireless Link Configuration, Security Configuration) of a selected AU (by its MAC address). 4.2.5.6.5 Show Link Capability by SU (AU only) Select this option to view all capabilities information (General, Wireless Link Configuration, Security Configuration) of a selected SU (by its MAC address). The default IP address is 10.0.0.1. 4.2.6.1.2 Subnet Mask The Subnet Mask parameter defines the subnet mask for the IP address of the unit. The default mask is 255.0.0.0. BreezeACCESS VL System Manual. The default value for the default gateway address is 0.0.0.0. 4.2.6.1.4 DHCP Client The DHCP Client submenu includes parameters that define the method of IP parameters acquisition.BAHETH24AQARI.COM/ckfinder/userfiles/files/C30-manual.pdf If the Operator ESSID Option is enabled at the AU, the Beacon frames transmitted by it will include both the ESSID and Operator ESSID. The SU shall BreezeACCESS VL System Manual. The ESSID of the AU with which the SU is eventually associated is defined as the Run-Time ESSID of the SU. Typically, the initial ESSID of the SU is configured to the value of the Operator ESSID. These frequencies are marked in the database as Adjacent to Radar, and will be treated the same as Radar Detected frequencies. BreezeACCESS VL System Manual. This message includes an indication whether the SUs should wait for this AU. If the SUs should wait, the message includes also the waiting time. During this time each SU searches for the AU in the defined frequencies subset. The range is 1 to 3600 seconds. The default is 60 seconds. BreezeACCESS VL System Manual. These frequencies will not be used when searching for a new frequency. TX Power will be set to the maximum defined by the country code. BreezeACCESS VL System Manual. The Multicast Modulation Level will be set to the minimum modulation level defined by the country code. The Burst Mode will be set to enable if the country code supports burst mode, and the burst duration will be set to default. The default is Disable. NOTE If the Best AU feature is not used, the SU associates with the first AU it finds whose ESSID or Operator ESSID is identical to its own ESSID. BreezeACCESS VL System Manual. The Number of Scanning Attempts parameter defines the number of times that the process will be repeated for all relevant frequencies. In addition, the higher the time that has passed since the last calculation, the lower the impact of history on the calculated average. If the average SNR is not in the configured target range, the AU transmits to the SU a power-up or a power-down message.https://www.sussexweddingservices.co.uk/wp-content/plugins/formcraft/file-upload/server/content/files/1629da455622c6---Creative-zen-v-4gb-manual.pdf The maximum value depends on several unit properties and parameters: The HW revision of the unit The Maximum Allowed Tx Power as defined for the applicable Sub-Band. 4.2.2.4 BreezeACCESS VL System Manual. In certain countries the Maximum EIRP of some equipment types cannot exceed a certain value. For information on how to view the Sub-Bands supported by the unit and the supported parameters’. If the selected option is Ethernet Status Control, then: BreezeACCESS VL System Manual. This feature can be used during maintenance or testing to avoid transmissions using undesired parameters. In addition, the Per SU Distance Learning feature is supported only when the Cell Distance Mode is set to Automatic. The Options are Automatic or Manual. BreezeACCESS VL System Manual. The range is 0 to 54 (Km). The value of 0 has a special meaning for No Compensation: Acknowledge Time Out is set to a value representing the maximum distance of 54 km. Available values for AU-BS and AU-SA range from 0 to 512. For AUS-BS and AUS-SA the range is from 0 to 8. The Spectrum Analysis submenu includes the following options: BreezeACCESS VL System Manual. Range: 2-30 seconds. Default value: 5 seconds. 4.2.6.2.15.2 Spectrum Analysis Scan Cycles The Spectrum Analysis Scan Cycle is the number of scanning cycles when performing Spectrum Analysis. This ANI mechanism is triggered by the rate of detected Physical Errors and it is modifying different thresholds affecting the immunity to specific interference types. BreezeACCESS VL System Manual. It is strongly recommended to consult with Alvarion experts before switching to manual mode and modifying any of the parameters. The general rules for using the Noise Immunity Control parameters are: In the SU, if performance (Modulation Level) is lower than expected based on the SNR, try switching to Manual mode without changing any of the parameters. The default is High. 4.2.6.2.18.https://www.lumisolar.pe/wp-content/plugins/formcraft/file-upload/server/content/files/1629da456980ed---creative-zen-v-mp3-player-manual.pdf6 Show Noise Immunity Select this option to view the current values of the Noise Immunity Control parameters, and some additional parameters of the ANI mechanism. BreezeACCESS VL System Manual. The default selection is Disable. BreezeACCESS VL System Manual. The default Network Management IP Address is 0.0.0.0 (all 10 addresses). 4.2.6.3.4 Delete a Network Management IP Address The Delete Network Management IP Address option enables deleting IP address entries from the Network Management IP Addresses list. The default AP Client IP Address is 0.0.0.0 (meaning none). system comprises a self-contained combination of an BreezeACCESS VL System Manual. VLAN implementation in BreezeACCESS VL units supports frame routing by port information, whereby each port is connected to only one VLAN. It enables defining the VLAN ID for management frames, which identifies remote stations for management purposes. This applies to all management applications using BreezeACCESS VL System Manual. Valid values: 1 to 4094 or 65535 (No VLAN). The default value is 65535. The Service Provider tag includes the Service Provider VLAN ID and the VLAN QinQ Ethertype.Available selections are Disable and Enable. The default selection is Disable. 4.2.6.4.1.4.2 Add Forwarding VLAN ID The Add Forwarding VLAN ID option enables adding a VLAN ID to the VLAN Forwarding List. BreezeACCESS VL System Manual. The Service Provider VLAN ID affects frames received from the Ethernet link port, as follows: A Service Provider tag, that includes the configured Service Provider VLAN ID (and the VLAN QinQ Ethertype) is inserted in all frames, both tagged and untagged, before transmission to the wireless link. On Both Ethernet and Wireless Ports - filters broadcast messages received from both the Ethernet and wireless link ports. The default selection is Disable. BreezeACCESS VL System Manual.BAHETH24CARS.COM/ckfinder/userfiles/files/C30-manual-transmission.pdf Even if according to the selected option in the Filter Options parameter, broadcast messages should be filtered, DHCP broadcasts are transmitted if this parameter is set to Enable. Select from the following options: Disable - DHCP Broadcast messages are filtered or transmitted according to the general filtering criteria in the Filter Options parameter. BreezeACCESS VL System Manual. The available range is 20 to 2000 seconds. The default value is 300 seconds. It forwards the SNAP to other AUs and Layer-2 networking equipment via its Ethernet port, to facilitate uninterrupted connectivity and BreezeACCESS VL System Manual. The new AU as well as the previous AU with which the SU was associated, will forward the SNAP messages to all other SUs associated with them. The default is Disable. 4.2.6.4.9 Ports Control (SU only) The Ports Control sub-menu includes the Ethernet Port Control option: 4.2.6.4.9.1 Ethernet Port Control The Ethernet Port Control option allows enabling or disabling non-management. For AUs with HW revision C the default is 4032, and for AUs with HW revision A or B the default is 2200. BreezeACCESS VL System Manual. The BreezeACCESS VL system uses a special mechanism based on detecting the presence of a carrier signal and analyzing the information contained in the transmissions of the AU to estimate the activity of other SUs served by the AU. NOTE The SNR measurement at the AU is accurate only when receiving transmissions from the applicable SU. If necessary, use the Ping Test utility in the Site Survey menu to verify data transmission. Default value: 5 Maximum Modulation Level BreezeACCESS VL System Manual. When the Adaptive Modulation Algorithm is disabled, a frame will be dropped when the number of unsuccessful retransmissions reaches this value. If the Maximum Modulation Level is set at the lowest possible level, the Adaptive Modulation algorithm has no effect. BreezeACCESS VL System Manual. The messages in the AU include SNR information on all the SUs associated with it. The Concatenation Parameters submenu includes: 4.2.6.5.10.1 Concatenation Option The Concatenation Option enables or disables the concatenation mechanism. The default is Enable. BreezeACCESS VL System Manual. The range is: 1256 to 2200 bytes for units with HW revision A or B 256 to 4032 bytes for units with HW revision C or higher The Default values are: 2200 for units with HW revision A or B 4032 for units with HW revision C or higher. When enabled, unicast DHCP messages pass, overriding the user filtering mechanism. The default is Disable DHCP Unicast. BreezeACCESS VL System Manual. Available values range from 0 to 2000 (milliseconds). The default value is 5 (milliseconds), enabling a maximum burst of (0.005 X CIR) Kbps after a period of inactivity of 5 milliseconds or more. BreezeACCESS VL System Manual. It enables defining the value of the VLAN Priority Threshold. The Real Time Control Protocol (RTCP) is used to control the RTP.If the administrator selects to prioritize only the RTP packets, then all the packets with an odd numbered destination port will always have Low priority. The packets with an even number for destination port will receive High priority, if the port number is included in the specified ranges. A comma is used to separate between entries. For example: 8900,9000-9005,9010,9016-9017. Delete All TCP Port Ranges: This option enables deleting all TCP port ranges from the list of priority port numbers. BreezeACCESS VL System Manual. The default option is Disable. BreezeACCESS VL System Manual. The range is from 3 to 254 (time slots). The default is 3. The default option is Enable. 4.2.6.6.4.2 UDP Port The UDP Port parameter defines the UDP port used by the DRAP protocol. The range is from 8000 to 8200. The default value is 8171. BreezeACCESS VL System Manual. WEP is defined in the IEEE 802.11 Wireless LAN standard and is based on the RSA’s RC4 encryption. When enabled, all data frames, including frames using management protocols such as Telnet, FTP, TFTP, SNMP, DHCP and ICMP, are encrypted. The default is Disable. BreezeACCESS VL System Manual. Mixed operation is not supported. An SU with Data Encryption Option enabled can accept non-encrypted data frames. When the Data Encryption Option is enabled, the maximum number of SUs that can associate with the AU is limited to 124. Use it only when absolutely necessary, perform the required actions as quickly as possible and disable it. The unit will return automatically to Promiscuous Authentication disabled mode after reset. BreezeACCESS VL System Manual. BreezeACCESS VL System Manual. BreezeACCESS VL System Manual. The Configuration File includes also parameters that are applicable only to BreezeNET B products. Do not attempt to change the default values of these parameters. Click on the Set button. This utility performs the same operation as Set Complete Factory Defaults, restoring the default factory configuration of all parameters, except to Passwords, general FTP parameters and AU’s Frequency. BreezeACCESS VL System Manual. BreezeACCESS VL System Manual Preparing the Indoor to Outdoor SU Cable. Some of the parameters are only applicable to one of the product lines. Identifiers, page 210 page 212. DisplayString (SIZE(0.32)) Read-only: Shadow software version number. Applicable to all units. DisplayString (SIZE(0.32)) Read-only: Shadow software version file name. MAC address Read-only: Unit hardware MAC address. BreezeACCESS VL System Manual. Integer Read-only: Unit type.Integer Read only. The supported supported (1) Burst Mode Option.The maximum supported burst duration.For SW version 4.0 and higher this is read-only, set to the IP Address of the unit. Applicable to all units.The IP IP address MASK of the FTP stack in the unit. The FTP IP address Default Gateway IP address. Applicable to all units. Integer Read-only. A table index for an 1-10 entry in the Management IP Addresses Table.Read-only: IP address The run-time IP address. If DHCP is used, the run-time IP address is the address given to the unit by the server. Alternatively the static IP address is used.Read-only: IP address The run-time subnet mask. If DHCP is used, the run-time subnet mask is the mask given to the unit by the server. VLAN ID of the Service Provider tag. Bridge aging time for devices learned from both the Ethernet and wireless link ports.Not applicable to BreezeNET B products. Enables or disables the relaying of broadcast messages to the wireless link. Applicable to AU only. Not applicable to BreezeNET B products. Ports Control parameters. When disabled, only data frames are blocked. Management frames are accepted.Air Interface parameters. ESSID Parameters. Applicable to all units. The Extended Service Set ID (ESSID) used to prevent the merging of collocated systems. Defines the minimum number of pulses to detect radar. Integer Range: 1 to 60 (minutes). The period in hours for assessment of radar activity when the Channel reuse algorithm is enabled. The selected mode of deciding on Cell Distance.Disassociation parameters. Applicable to AU. Disassociate ass SUs. Applicable to AU. Disassociate specified SU.Enables to turn the transmitter Off and On. If set to ethernetStatusControl, the unit will not transmit if the Ethernet link is down. This parameter can be configured only via the ethernet port. Not Integer applicable to BreezeNET B Range for Set: products.In this case the prioritization will be done using the DSCP sub- field. The size of the sub- field is 6 bits, so the range is 0 to 63.The Integer threshold of Precedence sub-field of IP ToS field from IP Header (RFC791) to be used when the ToS Prioritization Option is set to IP Precedence. Applicable to all units. Integer Delete all entries form UDP deleteAll(1), Port Ranges Table. Get cancelOperation (2) operation will return 1 UDP Port Range parameters. Applicable to all units.Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum number of HW Retries for a unicast data packet that has Low Priority.Applicable only if the Wireless Link Prioritization Option is enabled. An Integer address range for the IP 0 - 255 Filter entry.Returns Integer (0.7) types of encryption that are No encryption (0) supported.Not Integer applicable to BreezeNET B 20-4032 (bytes) products.The burst interval in milliseconds. Concatenation Parameters. Applicable to all units.Not applicable to units with SW version 4.0 and higher. Defines the maximum number of data frames that can be concatenated. Resets all the counters for all SUs in the MAC Address Database. Not accessible. It is used as an index in the MAC Pinpoint Table.Applicable to all units.The type of subscriber that was rejected by the AUS (AUS can serve up to 8 SUs. Only SU-3, SU-6 and SU-I are supported). The RB can be converted to BU or vice versa. BreezeACCESS VL System Manual Variables. In addition, each parameter entry also includes an indication as to whether the parameter is updated in run-time or whether the unit must be reset before the modification takes effect. Range Default Disable Disable Enable BreezeACCESS VL System Manual Run-Time (Disable after reset) Wrong Ethernet port Make sure that the speed and duplex operation mode settings in the PC match the configuration in the unit (the default is Auto Negotiation) BreezeACCESS VL System Manual. If necessary, change the excess of 15) operating frequency of the AU. Modulation Level 12.4 13.7 13.1 BreezeACCESS VL System Manual Corrective Action 15.8 25.1 26.4 17.7 24.7 28.9 30.1 16.9. To browse Academia.edu and the wider internet faster and more securely, please take a few seconds to upgrade your browser. You can download the paper by clicking the button above. Version 4.3. Revision 4.0A. June 2003. System Manual. Cat. No. Revision 4.0A 213482. All rights reserved. No part of this publication may be reproduced in any material form without the written permission ofTrade Names. Other brand and productStatement of Conditions. The information contained in this manual is subject to change without notice. Alvarion shall not beWarranties; Disclaimers. All Alvarion Ltd. (Alvarion) products purchased from Alvarion or through any of Alvarion’sExclusive Warranty. Alvarion warrants that the Product hardware it supplies and the tangible media on which any softwarePurchaser (the Warranty Period). Alvarion will, at its sole option and as Purchaser’s sole remedy,DisclaimerThis device complies with Part 15 of the FCC rules. Operation is subject to the following twoFCC Radio Frequency Interference Statement. This equipment has been tested and found to comply with the limits for a class A digital device,These limits are designed to provide reasonable protectionOperation of this equipment in a residential area is likely to cause harmful interference in which caseFCC Radiation Hazard Warning. To comply with FCC RF exposure requirements in section 1.1307, a minimum separation distance ofSafety Considerations. For the following safety considerations, “Instrument” means the BreezeACCESS units’ componentsCaution. To avoid electrical shock, do not perform any servicing unless you are qualified to do so. Important NoticeBS-GU Lithium Battery. Caution: Danger of battery explosion if incorrectly replaced or disposed of. Replace only with theDispose of used batterysLine Voltage. Before connecting this instrument to the power line, make sure that the voltage of the power sourcePower Cord. Use only the power cord supplied with the unit. Radio. The instrument transmits radio energy during normal operation. To avoid possible harmful exposureThe long-termOutdoor Unit and Antenna Installation and Grounding.