3m noisepro dosimeter manual

Forums: 

3m noisepro dosimeter manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:3m noisepro dosimeter manual.pdf
Size: 2566 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 26 May 2019, 12:10 PM
Rating: 4.6/5 from 651 votes.

Status: AVAILABLE

Last checked: 11 Minutes ago!

In order to read or download 3m noisepro dosimeter manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

3m noisepro dosimeter manualThe display will initialize and sequence to the “START” screen. 2. If “LOBAT” is in display, put new batteries in the NoisePro. Reset 3. Press and hold RESET softkey. The display counts down from 5 then shows “Sessions DELETED”. The run icon will appear in the lower right corner of the display. End Study 10. Regional noise standards specify criterion level. Dose - expressed in percent, it is the percent of the maximum exposure that has accumulated over the run time. It is recommended to check your regulations prior to data collection. Though it was filmed using the Edge eg5 intrinsically safe dosimeter, the calibration and use steps shown work for all models of the TSI Quest Edge. You can also check out the latest blog posts on sound level and noise monitoring from blog.RaecoRents.com. NoisePro User Manual Permission is hereby granted to copy and distribute this manual provided that this Copyright Page is included. This grant does not include permission to modify the manual s text or illustrations in any way. This manual may not be translated without obtaining permission in advance. Updates In the interests of continuous product improvements, 3M Quest Technologies reserves the right to make changes to product specifications without notice. To understand the latest updates that have been implemented into this product and to download the most current version of this user manual, visit our web site at Approvals UL, cul, MSHA, Ex and ATEX intrinsic safety approvals. Ex approval is in accordance with the ATEX Directive. Failure to observe the following procedures may result in serious personal injury To reduce the risk of explosion, do not mix used batteries with unused batteries or mix batteries from different manufacturers. Contains built-in lithium battery (for internal date and time back-up). Do not incinerate or dispose of in fire. Do not disassemble, alter, or re-construct. Warning! Failure to observe the following procedures could damage the instrument.http://www.internet-trade.cz/UserFiles/canon-850i-manual.xml

    Tags:
  • 3m noisepro dosimeter manual, 3m noisepro dosimeter manual pdf, 3m noisepro dosimeter manual download, 3m noisepro dosimeter manual instructions, 3m noisepro dosimeter manual free.

Read the manual before operation. Do not store in temperatures exceeding 60 C (140 F). Do not immerse in liquids. Condensation may damage your instrument. To reduce the risk of ignition of a flammable or explosive atmosphere, batteries must be changed only in a location known to be non-hazardous. Substitution of components may impair the accuracy of the instrument. Repair should be performed by authorized service personnel only. Caution! General The battery in this instrument has limited shelf-life, even if never used. A non-condensing environment is required for proper measurements. Battery run-time may be reduced when operating at lower than 0 C (32 F) temperatures. Batteries and Storage To reduce the risk of AA Alkaline batteries for leaking, it is recommended to: Remove the batteries from the housing whenever the NoisePro is stored for approximately 2 to 3 weeks or longer. Replace the batteries when LOBAT message appears on the display of the NoisePro. For more information on replacing the batteries or recommended battery types, please refer to Chapter 10, Replacing batteries and Approved batteries. Intended Use: The NoisePro is intended to measure sound pressure levels in air and provide personal noise exposure measurements. Recordings are performed in studies, and studies are grouped together in a session. A typical session consists of the recording of multiple studies in a work day, where the studies are separated by paused periods that allow time for work breaks and the lunch period. If you are using a DLX model, you can group studies in separate sessions and store as many as 100 sessions at one time in the instrument s memory. For the other NoisePro models, all of the studies stored in memory are part of the same session. Session results are derived values based on the results for all studies in the session. For example, the start and stop times of a session are determined by the first and last studies in the session.http://cowichanseniors.ca/userfiles/canon-8250-manual.xml The dose for a session is the accumulation of the dose results for all studies in the session. The maximum sound level for the session is the highest value of all the maximum sound levels obtained during the studies in the session. All measurements obtained for a study have their counterparts in session results. Logging In addition to making overall measurements, the NoisePro DL and DLX models save results periodically in a process known as data logging. Logged results are for a particular logging interval and don t depend upon other logged values or overall values for the study. The DL logs measurements automatically and needs no setup. For the DLX models, you can control what gets logged and the logging interval, and you can vary logging conditions in different sessions. Ar ea monitoring With its standard, shoulder-mounted microphone and dosimetry interpretations ( Interpreted summaries on page 44), NoisePro is optimized to make dosimetry measurements. It can also perform area monitoring, whether accumulating dosimetry information or not. Using NoisePro for area monitoring is equivalent to putting it to work as a sound level meter. Sound level meters require a different type of microphone attachment. While a shoulder-mounted microphone is best when monitoring for personal noise exposure, a rigid mounting is better for area monitoring. For that reason, Quest makes a boom- D 13 INTRODUCTION Session time line 3 mounted microphone as an optional attachment. For information about installing the boom microphone, see Assembling on page 7. You can perform area monitoring without recording data because sound levels are being measured even when no study is being performed ( SLM measurements on page 44). But you can also record the results if you wish using all the features of the NoisePro for dosimetry, including running studies automatically and communicating the results to external devices.http://ninethreefox.com/?q=node/13480 Session time line Figure 1 1 illustrates a recording period in which two studies are conducted and logging performed. For a DLX, this illustration represents the first of possibly multiple sessions recorded into memory because it is preceded by a Reset. For the DL and DLX models, the short dashed lines across the waveform indicate that logging is occurring. Session Study 1 Study 2 Logging Level (Pause) Start 1 End 1 Start 2 End 2 Reset Time Figure 1 1: Session time line D 14 4 INTRODUCTION Run Time Explanation of features Reset Start 1 End 1 Pause Start 2 End 2 Clears memory. If using a DLX model, the session counter is reset to 1. Opens the session and starts Study 1. This event marks the beginning of the session run time. Ends Study 1 and begins a pause in the session. The session run time clock stops. No data recording, but sound level monitoring could still take place. Begins Study 2. The session run time clock resumes. Ends Study 2. The session run time clock stops again. Run Time The time period of a study is the study s run time. The time period of a session is the sum of the run times of the individual studies in the session. The session run time begins at the beginning of the first study and ends at the end of the last study in the session, with pause times omitted. Use the cover Remember to replace NoisePro s cover when you don t need to get at the controls. It helps even when you re running an Auto-Run study. The cover guards against damage and prevents the unintentional operation of the instrument. For an orientation to the case and controls features discussed in this chapter, see NoisePro case and controls, on the facing page. Assembling If your instrument is a NoisePro DLX-1, you received a microphone cable assembly and separate microphone. For all other instruments, you received an integrated cablemounted microphone, but you may be using the optional boom-mounted microphone. For information about using the corrector, see SLM measurements on page 12.http://www.gongoff.com/images/bsr-femto-vodafone-manual.pdf NOTE: This microphone s grid cap is removable. Do not remove it and do not touch the diaphragm underneath. Class 1 microphone Position the microphone cartridge over the cable connector and screw to tighten. In accordance with the Class 1 microphone s packaging instructions, keep the microphone s center terminal from contacting first. After attaching the microphone to the cable, follow the instructions under Cable microphone on page 8 to connect the cable to the instrument. Random Incidence Corrector The purpose of this device is to improve the high frequency response of the Class 1 microphone under random incidence sound source conditions. To apply it, push over the tip of the microphone until the microphone seats against a lip in the corrector (approximately 1 mm from the end). D 18 8 FIRST TIME USE All other NoisePro models Frequency response curves for the microphone without the corrector are given under Class 1 microphone on page 87. Response curves with the corrector attached are provided with the Class 1 microphone. All other NoisePro models Cable microphone Attach by connecting the cable to the instrument. To install 1. Rotate the cable connector to align it properly with the Microphone Connector. There is only one way that it fits. 2. Push it straight in. The connectors automatically latch together. To remove 1. Grab the ring in the middle of the cable connector. 2. Pull it straight out. The ring slides to unlatch the connectors. Boom microphone The boom microphone is an optional type 2 microphone assembly. To install 1. Line up the boom connector with the Microphone Connector. There is only one way that it fits. 2. Plug in the boom connector. 3. Screw to tighten by rotating the boom connector s knurled ring clockwise. To remove 1. Unscrew to release the boom connector s knurled ring. 2. Pull the boom connector straight out of the Microphone Connector. See NoisePro case and controls on page 6 for the locations of these keys. That key is shown at right.https://glosunspa.com/wp-content/plugins/formcraft/file-upload/server/content/files/16291976f79c6d---83-honda-nighthawk-650-repair-manual.pdf Press to power NoisePro on. To power it off, press again and keep depressed during a countdown. The symbol is, in reality, for the same key but denotes the key s escape function (backing up to a previous display) that you use to move backward along a display path. NOTE: You will not be able to power NoisePro off while a study is running. Verifying batter y power With the instrument on, look in the lower right corner of the display for a symbol like the one shown at the right. The dark bar in this icon shortens to the right as battery power decreases. When battery power gets down to an estimated eight hours of run time, the battery icon is replaced by the word, LOBAT. When LOBAT appears, consider replacing the AA batteries to ensure enough power to complete your studies ( Replacing batteries on page 65). Esta bl ishing oper ating conditions NoisePro is shipped with default settings that enable you to get started right out of the box, but you may want to changes some of the settings. Displays and the clock You may want to customize display characteristics and verify, or change, clock settings before running studies. To work in Setup displays 1. In the Start display, press until SETUP is highlighted. 2. Press. The Setup display appears. D 20 10 FIRST TIME USE Selecting logging options (DLX models only) 3. Press to make your selection. Select TIME-DATE to set the clock. Select DISPLAY to control backlighting and pick descriptors. 4. For details on working in these and other setup displays, see Setup display on page When finished changing settings in any Setup display, press to escape to the previous display (more than once to keep backing up to previous displays). Selecting logging options (DLX models only) In the DLX, you can choose logging parameters such as what gets logged and at what rate. See Logging on page 26 to learn about these procedures.BAIDUVPN.COM/upload/files/canon-d90-manual-pdf Choosing dosimeter setups All NoisePro models operate with multiple dosimeters at once, and each dosimeter can be assigned a setup from among the nine setups available. For information about these setups, including how to view them, change them and assign them to the dosimeters, see Chapter 4, Configuring dosimeters. Calibr ating It s wise to calibrate both before and after each study. The instrument will display precalibration and post-calibration information for your field review plus store it with the data for later review and analysis (Chapter 2, Calibrations, ). D 21 FIRST TIME USE Preparing to measure 11 Pr eparing to measur e Reset session memory, attach the windscreen and mount the microphone and case in accordance with your purposes. Reset operation A Reset removes all data from session memory, so make sure you no longer need that stored data before resetting. You must be in the Start display to perform a Reset. If in any other display, complete whatever task you re doing in that display and press one or more times to get back to the Start display. In the Start display, press the RESET softkey and hold until told in the display that all studies have been cleared. Attach the windscreen Use the NoisePro windscreen for all measurements. A windscreen reduces errors due to wind turbulence and helps prevent microphone damage. After calibrating, push the windscreen over the tip of the microphone. It stretches for a snug fit. Microphone positioning You can use NoisePro for both dosimetry (personal monitoring) and sound level meter (SLM) measurements, but microphone positioning should be different for these two conditions. Dosimetry Clip the microphone to your shirt or collar (Figure 2 1) as high on the shoulder as possible and away from the neck. If the noise seems to come from one direction, place it on the shoulder closest to the noise source. During monitoring, keep clothing from coming into contact with the windscreen to avoid erroneous noise artifacts.https://hellnocancershow.com/wp-content/plugins/formcraft/file-upload/server/content/files/162919770ca067---83-honda-nighthawk-manual.pdf If you have the optional microphone clips, use them to keep the cable from disturbing the microphone position (( Optional accessories on page 100). NOTE: To use the DLX-1 model for dosimetry, attach the Random Incidence Corrector furnished with the Class 1 microphone. 22 12 FIRST TIME USE Microphone positioning Figure 2 1: Shoulder-mounted microphone Clip the instrument s belt clip over your belt. If using the optional vibrating belt clip (or need to go back to the standard belt clip) see Exchanging belt clips on page 67 to install the appropriate belt clip for your purposes. SLM measurements You should do your best to minimize sound reflections, diffractions and absorptions caused by nearby objects, including the operator (free field condition). Avoid placement near a wall or in a corner.when doing free field monitoring, do not use the Class 1 microphone s Random Incidence Corrector. If reflections, diffractions or absorptions from nearby objects are present, use the corrector for random incidence monitoring. Whenever possible, attach the instrument to a tripod. Quest offers two types of tripods as optional equipment ( Tripods on page 100). D 23 FIRST TIME USE Measuring noise levels 13 Orient the microphone depending upon whether you are doing free field or random incidence monitoring. During or after a study, you can open the Results display to examine a wide variety of level, average and dose measurements obtained with multiple dosimeter setups. Running studies Start and stop studies using the key shown at the right. When a study is running, a Run Icon ( )appears just to the left of the battery icon at the lower right corner of the display. When the session is paused, a Pause Icon ( ) replaces the Run Icon. After a Reset that clears memory, a Session Closed Icon ( ) appears in that location. Viewing results Examine noise measurements and other information in the Results display ( Results display on page 41). To view results 1.https://opalsolar.com.au/wp-content/plugins/formcraft/file-upload/server/content/files/16291978441d5e---83-honda-shadow-vt500c-manual.pdf In the Start display, press to highlight VIEW CURRENT STUDIES. 2. Press. The Results display appears (Figure 6 2). Press the LEVEL, AVG, DOSE and SUMRY softkeys to cycle through measurements and a measurement summary. Press to switch between the instrument s dosimeters and view measurement results for each dosimeter. 3. Press to return to Start display. You can segregate studies into separate sessions by closing the current session. A new session will open when you start the next study. To close a session 1. In the Start display, press until CLOSE SESSION is highlighted. 2. Press. The session closes immediately. A few wor ds a bout displays The NoisePro starts in the Start display, which is shown below. From there you can branch to other displays, and in some cases to even more displays in a cascading fashion. Navigation Line Session Closed Icon Battery Icon Menu Options Softkey Functions Softkeys Figure 2 2: Start display and softkeys Most displays contain Menu Options, a Navigation Line at the top and Softkey Functions along the bottom. Select a menu option with the keys. The Navigation Line tells you what displays preceded the current display along a display path. To get back from any display to the previous display in the cascade, the general rule is to press (In some cases you re taken back automatically.) The Softkey Functions identify the purpose of the softkeys that are located directly below the display. Softkey functions are generally different for different displays. D 25 CHAPTER Calibrations 3 Noise measurements are only as good as the calibration of the measuring instrument. To assure yourself that your NoisePro dosimeter is functioning within normal tolerance limits, return it to the factory periodically for a factory recalibration ( Factory service on page 71). This chapter explains how you can verify measurement calibration as part of your normal operating procedures.BAHETH24AQARI.COM/ckfinder/userfiles/files/canon-d880-manual.pdf Field calibr ator The Quest calibrator is a portable device emitting sound at a fixed frequency and sound level. For some calibrators, the signal frequency and sound level can be selected. For all calibrators, the indicated frequency and sound level is specified on the calibrator. NOTE: Calibrators can be affected by changes in altitude and barometric pressure, and sometimes corrections are necessary. See your calibrator s user manual. Calibrate the calibrator The conformance of a field calibrator to its specifications should be periodically checked as well. To have a Quest calibrator checked, return it to a factory-authorized service center ( Factory service on page 71). Perfor ming a field calibr ation Preliminary steps Stop the current study. You cannot calibrate while a study is running. If the windscreen is on the microphone, remove it. The instrument must be ON with the microphone connected to it. Check the instrument battery indicator. If LOBAT is showing, replace the instrument s batteries before proceeding ( Replacing batteries on page 65). D 26 16 CALIBRATIONS Assemble Check the calibrator battery indicator. If the LOBAT indicator is ON, see the calibrator s user manual to replace the calibrator batteries before proceeding. If the calibrator has a selectable frequency setting, set it to 1000 Hz. Assemble Refer to Figure 3 1 for either the cable-mounted or boom-mounted (type 2 only) microphone. Type 1 and type 2 microphones require different adapters. To prepare to calibrate 1. Turn the calibrator ON. 2. Place the adaptor on the microphone. 3. Orient for either the cable-mounted or boom-mounted microphone as illustrated in Figure 3 1, then press the adapter into the calibrator. Adapter Cable Microphone Orientation Figure 3 1: Calibration orientations and assembly Boom Microphone Orientation D 27 CALIBRATIONS Calibration display 17 Calibration display Use the Calibration display to view and save calibrations (Figure 3 2). Pre-calibration Post-calibration Figure 3 2: Calibration display The Calibration display always shows the latest Pre-and Post-calibration results. Times are reported according to either the 12-hour or the 24-hour clock convention, according to your selection ( Time-Date on page 25). If you re using a NoisePro or NoisePro DL, the Pre-calibration information applies to a calibration done with a cleared memory (after a Reset). For a DLX model, you can also save a Pre-calibration value between sessions. The Post-calibration information applies to a calibration done after any study in the session and is stored with the study that it follows. When two or more calibrations are done after a study, only the last one is saved. When saving a Pre-calibration value, you may adjust it so that it agrees with the calibrator s output level. A Post-calibration value can only be saved as is you cannot adjust it. The Post-calibration value indicates whether there was any change in the instrument that affected its calibration during the study. Saving a calibration A Pre-calibration is saved only if the instrument passes a test of the calibration. A Post-calibration is saved automatically without being tested. For both Pre- and Postcalibration measurements, you should verify the results in the Calibration display. To save a Pre-calibration 1. Prepare the equipment ( Assemble on page 16). 2. Press the CAL softkey in the Start display. The Calibration display appears (Figure 3 2). 28 18 CALIBRATIONS Calibration display 3. CALIBRATE is highlighted in the display. Press. The Calibration Save display appears (see Figure 3-3). The indented Calibration Assignment shows in the Navigation Line. Figure 3-3: Calibration Save display 4. Press to adjust the value equal to the calibrator s labeled output level. 5. Press. A test progress bar appears. At the end of the test, either PASS or FAIL briefly appears above the bar, then the Calibration display reappears. Pass - the new calibration results are posted in the Pre-calibration section of the Calibration display. Fail - The new calibration results are not saved. The previous Pre-calibration results remain in the Calibration display. For assistance when calibration fails, see Troubleshooting on page 69. NOTE: When calibrating a Type 1 microphone (used on the NoisePro DLX-1), adjust the sound pressure level to 0.1 db lower than the actual SPL produced by the calibrator. For example, when the calibrator is measuring at db, adjust the level to db. 29 CHAPTER General setup 4 NoisePro comes ready for immediate use with default settings, but you can change many settings to configure it for your individual purposes. For example, you should check the time to verify that it matches your local time ( Time-Date on page 25). This chapter explains the setup procedures that are available as menu options in the Setup display. There are also setup procedures for individual dosimeters (Chapter 4, Configuring dosimeters. ) NOTE: User-defined settings may only be changed when a study is not running. Also, you cannot enter any setup display when security setup is enabled unless you know the setup code ( Secure Setup Mode on page 49). Setup display The Setup display is an option on the Start menu. To get to the Setup display 1. In the Start display, press to highlight Setup. (If not already in the Start display, press one or more times to get there. You may need to complete an operation in your current display before using.) 2. Press. The Setup display appears (Figure 4 1). Menu options Figure 4 1: DLX model Setup display D 30 20 GENERAL SETUP Auto-Run Auto-Run In addition to running studies manually as explained under Running studies on page 13, you can operate in several Auto-Run modes. In the Date and Days of Week modes, NoisePro is fully automatic. After setting up and enabling one of these modes, switch the power off, position the microphone and then walk away. When the run date and time arrives, NoisePro turns itself on, runs the study, then turns itself off again. Timed Run is a semi-automatic mode. After setting up and enabling that mode, start a study by pressing. When the preset run time arrives, NoisePro stops the study automatically. Choose an Auto-Run mode in the Auto-Run display. Select AUTO-RUN in the Setup display, then press. The Auto-Run display appears (Figure 4 2). Figure 4 2: Auto-Run display Date mode For all models, you can specify the start and run times for the date selected. For a DLX, you can select up to four dates. NOTE: The NoisePro Auto-Run feature operates on a one-year calendar. In Auto- Run Date mode, you cannot select a date more than 364 days ahead. For all other models, press the softkey labeled 1. If the key label is preceded by a negative sign (disabled), press it again to enable that selection. The Date Setup display appears with the Auto-Run Banner highlighted (Figure 4 3). Timed Run mode Set a time in Timed Run mode when you want to start a study manually but end it automatically. To set in Timed Run mode 1. In the Auto-Run display, cursor to highlight MODE (Figure 4 2). 2. Press once or twice until TIMED RUN appears on the right. 3. Press the Time softkey. The Timed Run Setup display appears (Figure 4 3). Timed-Run Banner Run time (HH:MM:SS) Time softkey Figure 4 4: Timed Run Setup display 4. The Timed-Run Banner is highlighted. If you see OFF below the banner, enable the function by pressing the softkey again. 5. Press to highlight the first of three time fields (HH:MM:SS). 6. Press, to modify, then press to highlight the next field. 7. Repeat steps 5 6 for the seconds field. The highlighting will return to the Timed- Run Banner at the top. 8. Press to escape the display. D 33 GENERAL SETUP Auto-Run 23 Days of Week mode Set for regular daily studies. For each of two setups, you can select the days of the week on which you want to run one or two studies. You can select any number of days, any time of the day and run times up to 100 hours. When you enable Auto-Run after choosing the Days of Week mode, NoisePro starts and stops studies according to your settings for as long as it can record or until you disable it. The Days of Week Setup display appears(figure 4 5). If the letter is showing, that day is enabled. If a dash ( ) is showing, the day is disabled. 12. Repeat step 11 for all the days of the week. 13. If done with the setup, press to escape the display. You must enable it to run studies according to the mode, date and time settings you previously selected. When you enable and power down, the time and date when the instrument will turn itself on will be displayed. NOTE: If you set multiple auto-runs, make sure that you set the start time of each to occur no earlier than 2 minutes after the end of the previous auto-run. You must switch NoisePro off for these modes to operate. D 35 GENERAL SETUP Time-Date 25 Time-Date Select this display to change clock settings, for example to change the hour to adapt to a time zone or daylight savings time difference. In addition to setting the time and date, you can specify whether your display reads in the 12-hour or 24-hour format. To change settings 1. In the Time-Date display, press to select TIME, DISPLAY or DATE. 2. Press to advance the cursor into the data field. 3. Press to modify the setting. 4. Press to advance the cursor, either into the selection s next data field or to a different selection. 5. Repeat all steps above to change other settings in this display. 6. Press to escape the display. NOTE: You can only escape the display when TIME, DISPLAY or DATE is highlighted. Prj Time Set a Projected Time when you want to calculate dosages for a time that is different than the Run Time. This setting applies to all active dosimeters (global setting). To set Projected Time 1. In the Prj Time display, press to highlight the setting. 2. Press to select a new setting 3. Press to change it. 4. Press to escape the display. D 36 26 GENERAL SETUP Logging Logging If you re using the DLX, the Logging Setup display, shown in Figure 4 6, allows you to set the logging rate and two logging thresholds. You can choose which measurements are logged by selecting Y (enabled) or N (not enabled). If a measurement is not available, D is displayed after the descriptor. Table 4 1 further explains the menu options. Figure 4 6: Logging Setup display NOTE: Logging settings may be changed only during a closed session. You can reset to close the session ( Reset operation on page 11). For DLX models, you can also close a session in the Start display ( Closing sessions on page 14). Table 4 1: Explanation of logging options Logging Menu options AVG (1 4) SMAX FMAX, IMAX SMIN FMIN, IMIN LPK SCEIL FCEIL INTERVAL Explanations a Time-average sound level for each dosimeter. Maximum level at slow time response. Maximum level at fast time response. Minimum level at slow time response. Minimum level at fast time response. Peak level (unaffected by time response setting). Measure of how long during a logging interval that the level at slow time response exceeds the Slow Ceiling threshold. Measure of how long during a logging interval that the level at fast time response exceeds the Fast Ceiling threshold. Logging interval time (range: 1 second to 60 minutes in 11 steps).You can also enable and disable logging for the maximum and minimum levels and for the ceiling times. NOTE: If D is shown for a dosimeter, that dosimeter is currently disabled ( Assigning a setup to a dosimeter on page 37). 1. In the Logging Setup display, cursor to highlight the option. 2. Press to toggle the setting to Y or N. 3. Press to escape the display. To change a ceiling setting 1. In the Logging Setup display, cursor to highlight either SCEIL or FCEIL below the toggle options (they are followed by threshold settings). 2. Press to move the highlighting to the current ceiling setting. 3.